LCR meters (RLC meters), inductance and capacitance meters

Electrical inductance, electrical capacitance and electrical resistance are three basic quantities, the measurement of which has a common name: impedancemetry. Instruments for measuring inductance (L), capacitance (C) and resistance R are called LCR meters, and in the old literature RLC meters.

Below are the most popular models LCR meters (RLC meters). Regarding prices and delivery times for the entire range of instrumentation, simply call us or write to us at E-mail and we will be happy to answer your questions.

Model A photo Short description
LCR (RLC) meters of the Sourcetronic company
Sourcetronic
ST2829A
ST2829B
ST2829C
Sourcetronic ST2829 - A series of laboratory LCR meters with maximum capabilities

Product code: 1000703

ST2829 Series LCR Sourcetronic Laboratory Meters
Frequency: 20Hz - 300KHz (model ST2829A)
Frequency: 20Hz - 500kHz (model ST2829B)
Frequency: 20Hz - 1MHz (model ST2829C)
Basic Accuracy: 0.05%.
Inductance measurement range: 0.00001 µH to 9.9999 kH.
Capacitance measurement range: 0.00001 pF to 9.99999 F.
Resistance measurement range: 0.00001 Ω to 99.9999 MΩ.
Q-factor measurement range: from 0.0001 to 99999.
Measuring voltage 5 mV - 10 V (RMS), measuring current 50 μA - 100 mA (RMS).
Built-in 10V/100mA DC bias voltage source.
17.7 cm color graphics screen (800 x 480 resolution). Weight: 13 kg.
Interfaces: Ethernet/LXI, USB, RS-232 (standard); IEEE-488.2 (GPIB) (option).
Precision LCR Meters with Maximum Capabilities
LCR (RLC) meters of the Agilent Technologies company
Agilent
4263B
Agilent 4263B - RLC Meter. 100 Hz - 100 kHz. RLC meter. 100 Hz - 100 kHz.

Accuracy: 0.1%. Test signal level: 20 mV - 1 V (RMS).
Frequencies: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz. Measurement: 25 ms.
Agilent
4288A
Agilent 4288A - RLC Meter. 1 kHz, 1 MHz. RLC meter. 1 kHz, 1 MHz.

Accuracy: 0.07%. Test signal level: 100 mV - 1 V (RMS).
Frequencies: 1 kHz and 1 MHz. Measurement: 6.5 ms.
Agilent
E4980A
Agilent E4980A - RLC Meter. 20 Hz - 2 MHz. RLC meter. 20 Hz - 2 MHz.

Accuracy: 0.05%. Test signal level: 0 - 2 V (RMS).
Measurement: 5.6 ms. Interfaces: LAN, USB and GPIB.
Agilent
4285A
Agilent 4285A - RLC Meter. 75 kHz - 30 MHz. RLC meter. 75 kHz - 30 MHz.

Accuracy: 0.1%. Test signal level: 5 mV - 2 V (RMS).
Frequencies: 75 kHz - 30 MHz in 100 Hz steps. Measurement: 30ms.

Economy offer

Tehencom company offers both completely new devices, as well as used and fully restored in the factory. The cost of refurbished devices can be 1.5 - 2 times lower than the cost of new ones. All proposed refurbished devices are 100% operational, meet the technical requirements of the manufacturer and are provided 1 year warranty.

Below are some of the many refurbished instruments we offer.

Model A photo Short description
LCR (RLC) meters of the Agilent Technologies company (refurbished)
Agilent
E4980A
Agilent E4980A - RLC Meter. 20 Hz - 2 MHz (rebuilt). RLC meter. 20 Hz - 2 MHz.

Accuracy: 0.05%. Test signal level: 0 - 2 V (RMS).
Measurement: 5.6 ms. Interfaces: LAN, USB and GPIB.