LCR meters (RLC meters), inductance and capacitance meters
Electrical inductance, electrical capacitance and electrical resistance are three basic quantities, the measurement of which has a common name: impedancemetry. Instruments for measuring inductance (L), capacitance (C) and resistance R are called LCR meters, and in the old literature RLC meters.
Below are the most popular models LCR meters (RLC meters). Regarding prices and delivery times for the entire range of instrumentation, simply call us or write to us at E-mail and we will be happy to answer your questions.
Model | A photo | Short description |
LCR (RLC) meters of the Sourcetronic company | ||
Sourcetronic ST2829A ST2829B ST2829C |
Product code: 1000703 |
ST2829 Series LCR Sourcetronic Laboratory Meters Frequency: 20Hz - 300KHz (model ST2829A) Frequency: 20Hz - 500kHz (model ST2829B) Frequency: 20Hz - 1MHz (model ST2829C) Basic Accuracy: 0.05%. Inductance measurement range: 0.00001 µH to 9.9999 kH. Capacitance measurement range: 0.00001 pF to 9.99999 F. Resistance measurement range: 0.00001 Ω to 99.9999 MΩ. Q-factor measurement range: from 0.0001 to 99999. Measuring voltage 5 mV - 10 V (RMS), measuring current 50 μA - 100 mA (RMS). Built-in 10V/100mA DC bias voltage source. 17.7 cm color graphics screen (800 x 480 resolution). Weight: 13 kg. Interfaces: Ethernet/LXI, USB, RS-232 (standard); IEEE-488.2 (GPIB) (option). Precision LCR Meters with Maximum Capabilities |
LCR (RLC) meters of the Agilent Technologies company | ||
Agilent 4263B |
RLC meter. 100 Hz - 100 kHz. Accuracy: 0.1%. Test signal level: 20 mV - 1 V (RMS). Frequencies: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz. Measurement: 25 ms. |
|
Agilent 4288A |
RLC meter. 1 kHz, 1 MHz. Accuracy: 0.07%. Test signal level: 100 mV - 1 V (RMS). Frequencies: 1 kHz and 1 MHz. Measurement: 6.5 ms. |
|
Agilent E4980A |
RLC meter. 20 Hz - 2 MHz. Accuracy: 0.05%. Test signal level: 0 - 2 V (RMS). Measurement: 5.6 ms. Interfaces: LAN, USB and GPIB. |
|
Agilent 4285A |
RLC meter. 75 kHz - 30 MHz. Accuracy: 0.1%. Test signal level: 5 mV - 2 V (RMS). Frequencies: 75 kHz - 30 MHz in 100 Hz steps. Measurement: 30ms. |
Economy offer
Tehencom company offers both completely new devices, as well as used and fully restored in the factory. The cost of refurbished devices can be 1.5 - 2 times lower than the cost of new ones. All proposed refurbished devices are 100% operational, meet the technical requirements of the manufacturer and are provided 1 year warranty.
Below are some of the many refurbished instruments we offer.
Model | A photo | Short description |
LCR (RLC) meters of the Agilent Technologies company (refurbished) | ||
Agilent E4980A |
RLC meter. 20 Hz - 2 MHz. Accuracy: 0.05%. Test signal level: 0 - 2 V (RMS). Measurement: 5.6 ms. Interfaces: LAN, USB and GPIB. |